Dr. Vaibhav Sinha

Educator, Researcher, Administrator and Entrepreneur


Curriculum vitae


[email protected]


+1-614-805-1037



Feasibility studies on explosive detection and homeland security applications using a neutron and x-ray combined computed tomography system


Journal article


Vaibhav Sinha, A. Srivastava, Hyoung K. Lee, Xin Liu
Defense, Security, and Sensing, 2013

Semantic Scholar DOI
Cite

Cite

APA   Click to copy
Sinha, V., Srivastava, A., Lee, H. K., & Liu, X. (2013). Feasibility studies on explosive detection and homeland security applications using a neutron and x-ray combined computed tomography system. Defense, Security, and Sensing.


Chicago/Turabian   Click to copy
Sinha, Vaibhav, A. Srivastava, Hyoung K. Lee, and Xin Liu. “Feasibility Studies on Explosive Detection and Homeland Security Applications Using a Neutron and x-Ray Combined Computed Tomography System.” Defense, Security, and Sensing (2013).


MLA   Click to copy
Sinha, Vaibhav, et al. “Feasibility Studies on Explosive Detection and Homeland Security Applications Using a Neutron and x-Ray Combined Computed Tomography System.” Defense, Security, and Sensing, 2013.


BibTeX   Click to copy

@article{vaibhav2013a,
  title = {Feasibility studies on explosive detection and homeland security applications using a neutron and x-ray combined computed tomography system},
  year = {2013},
  journal = {Defense, Security, and Sensing},
  author = {Sinha, Vaibhav and Srivastava, A. and Lee, Hyoung K. and Liu, Xin}
}

Abstract

The successful creation and operation of a neutron and X-ray combined computed tomography (NXCT) system has been demonstrated by researchers at the Missouri University of Science and Technology. The NXCT system has numerous applications in the field of material characterization and object identification in materials with a mixture of atomic numbers represented. Presently, the feasibility studies have been performed for explosive detection and homeland security applications, particularly in concealed material detection and determination of the light atomic number materials. These materials cannot be detected using traditional X-ray imaging. The new system has the capability to provide complete structural and compositional information due to the complementary nature of X-ray and neutron interactions with materials. The design of the NXCT system facilitates simultaneous and instantaneous imaging operation, promising enhanced detection capabilities of explosive materials, low atomic number materials and illicit materials for homeland security applications. In addition, a sample positioning system allowing the user to remotely and automatically manipulate the sample makes the system viable for commercial applications. Several explosives and weapon simulants have been imaged and the results are provided. The fusion algorithms which combine the data from the neutron and X-ray imaging produce superior images. This paper is a compete overview of the NXCT system for feasibility studies of explosive detection and homeland security applications. The design of the system, operation, algorithm development, and detection schemes are provided. This is the first combined neutron and X-ray computed tomography system in operation. Furthermore, the method of fusing neutron and X-ray images together is a new approach which provides high contrast images of the desired object. The system could serve as a standardized tool in nondestructive testing of many applications, especially in explosives detection and homeland security research.


Share



Follow this website


You need to create an Owlstown account to follow this website.


Sign up

Already an Owlstown member?

Log in